🔧 How to Fix Hexing Err 03Token Expired

⚡ Quick Answer

Err 03 means: The token was generated too far in the past and the meter's TID temporal counter has surpassed it. Fix: Discard the old token. Purchase a fresh credit token. If this happens repeatedly, the meter may need a TID rollover update (KCT).

🟢 low
DIY fixable

What Causes Err 03?

The token was generated too far in the past and the meter's TID temporal counter has surpassed it. The token's timestamp falls outside the acceptable window.

Root cause: Token generated days or weeks before being entered; TID counter has advanced beyond the token's validity window.

🛠How to Fix

Discard the old token. Purchase a fresh credit token. If this happens repeatedly, the meter may need a TID rollover update (KCT).

📞When to Call Your DisCo

Contact your DisCo if the error persists after trying the fix steps, or if you're uncomfortable working with electrical equipment.

AEDC

Abuja Electricity

📞 08039070070

💬 08152141414, 08152151515

✉️ customercare@abujaelectricity.com

BEDC

Benin Electricity

📞 0700-000-2332

✉️ servicedesk@beninelectric.com

EKEDC

Eko Electricity

📞 0708-067-1170

✉️ customercare@ekedp.com

EEDC

Enugu Electricity

📞 084-700-100

💬 08150826060, 08150826061

✉️ customerservice@enugudisco.com

IBEDC

Ibadan Electricity

📞 07001239999

✉️ customercare@ibedc.com

IKEDC

Ikeja Electric

📞 0201-7000-250

💬 09088951626

✉️ customercare@ikejaelectric.com

+ 5 more DisCos — see all contacts

⌨️Hexing Useful Shortcodes

CodeWhat It Does
801Current available credit balance
804Internal hardware serial number
807Hardware status register (hexadecimal/binary fault codes)
808Instantaneous power draw in kW (real-time load check)
809Current Tariff Index (verify vending TI alignment)
865Validate operational mode (normal vs factory test)
800Total cumulative active energy since manufacture
830Recall last token number entered
812Cancel/mute audible piezoelectric alarm